Updated

Quick answer: The eTM-8006 lists 800V, 6A and 4800W. Keithley 2260B-800-2 and GW Instek PSW 800-2.88 list 800V, 2.88A and 720W. On the 720W models, maximum voltage and current cannot be combined simultaneously.

On this page
  1. 800V model comparison
  2. Why power limits matter at 800V
  3. Choose for the required operating point
  4. Controls, protection and integration
  5. Installation and load checks
  6. Considering a 500V test instead?
\"800V

800V model comparison

ModelMaximum voltageMaximum currentRated output power
ETOMMENS eTM-8006800V6A4800W
Keithley 2260B-800-2800V2.88A720W
GW Instek PSW 800-2.88800V2.88A720W

Why power limits matter at 800V

For either 720W multi-range model, the power ceiling at 800V is 720W ÷ 800V = 0.90A. The 2.88A headline applies within the permitted voltage/power envelope; it is not 2.88A at 800V. At 250V, 720W ÷ 250V = 2.88A. These calculations clarify the ratings; the manufacturer’s detailed operating limits still apply.

Choose for the required operating point

The eTM-8006 has a larger stated output-power rating. That may fit a higher-current high-voltage test, but it does not by itself prove better accuracy, noise or transient response. Compare those properties separately with matching load and measurement conditions.

Controls, protection and integration

Keithley’s series documentation lists programmable rise/fall behaviour; GW Instek’s PSW documentation describes multi-range operation. For every candidate, confirm the exact interfaces, command support, protection behaviour and optional configurations. Do not infer programmability or remote SENSE from a different model in the same family.

Installation and load checks

  • Verify mains capacity, input configuration and environmental conditions.
  • Specify output connections, insulation and the manufacturer’s discharge procedure.
  • Identify capacitive, inductive or energy-returning loads and obtain documented compatibility.
  • Record your required voltage/current points and acceptance measurements for the purchase decision.

Considering a 500V test instead?

Select the voltage class from the actual load requirement. A higher maximum voltage is not automatically better for lower-voltage resolution, measurement accuracy or cost. Compare the appropriate range and available current at your test point.

Practical checks

CheckWhat to verify
800V operation720W ÷ 800V = 0.90A at the power limit.
Current requirementCompare current available at the actual test voltage.
ControlCheck the exact command set, interface and rise/fall controls.
InstallationConfirm mains power, cabling, connectors and discharge procedure.

Compare a supply for your test

Explore variable DC power supplies or review 800V DC power supplies. Specify your operating voltage, current, power, load type and required controls for selection a configuration.

For a lower-voltage high-power test, compare 500V DC power supplies against your actual operating point.

Sources